Data: 2009-12-06 23:07:15 | |
Autor: Tomasz Smereczyński | |
Wadliwe skrzydła OMS | |
Hej wszystkim,
w dniu 6.12 otrzymałem od firmy OMS maila o wadliwej serii skrzydeł. Oto on : Ocean Management Systems Inc. (OMS) ANNOUNCES Safety Replacement OF BCS SEAL RING (Item # BCA 500) Ocean Management Systems, Inc. (OMS) has notified the U.S. Consumer Product Safety Commission (CPSC), that they are voluntarily recalling approximately 19,790 Sealing Rings BCA-500. Molding variations in this part as used in the OMS Buoyancy Control System (BCS) could cause cracking or breakage of part, resulting in rapid loss of buoyancy, creating a potential drowning hazard. While this variation is not present in every Seal Ring (Item # BCA 500), it would be difficult to determine in the field which Seal Rings are suspect. Therefore they are requiring that all Seal Rings be updated with new assemblies. All NEW seal rings are equipped with reinforcement at critical areas. 19 failures have been reported of 19 failures. These failures were discovered during inspection, with no reports of injuries or death. For further instructions or if you have questions, you can call OMS at 1-8845-692-3600, email at recall@omsdive.com or look on the website for further information at http://www.omsdive.com/bca500-recall.html W poniższym linku wymienione są wadliwe serie produktów : http://www.omsdive.com/bca500-recall.html |
|